Six signal checks used to leave from the same mast. If its recorder went quiet, the bridge lost all six readings at once. We asked the keepers across the water to call us as well. One calls the mast directly. Another sends a message through the exchange and waits for the far bank to answer. The log now has a column for who heard the reply. It matters which end is holding the pencil.
Earlier watch notes
· Engineering watch
Where the Bell Wire Ends
Iri let me ring the test bell at the listening desk. The hammer moved briskly. Down the passage its wire ended on an empty hook. We went through the board with a pencil and gave each bell three possible marks: a keeper answers, the bell has been taken down, or the far end still hangs loose. Taking a bell down and finding it a keeper make quite different entries in the book.
Our passenger launch made Stillwater while the freight coxswain was still holding off in the dark. From shore both had looked like little white dots on the same stretch of water. We gave each coxswain a line in the watch book. The empty line beside Freight kept the hand lamp on duty for six more minutes.
In the blue book the registrar’s address had a neat correction in fresh ink. I asked the relief keeper to fetch the book she had actually opened when she lit the spare desk. It was red. Both books carried the harbourmaster’s seal. The red one had a loose hinge and opened by itself at the old address.
The exchange keeper showed me three copies of the signal register. I asked which one she could fetch with the west quay sealed. She looked at the locker key in her palm. We spent the rest of the watch drawing a second store across the channel. We pencilled in the crossing for the first copy. That part still needs a boat.
A pilot laid her old chart over the fresh sheet from the schoolroom. The headlands matched exactly. She put her thumb on a narrow inlet where she had taken a sounding herself. On the fresh sheet you could see clean paper through the pinhole. She lent us the old chart and asked us to try that inlet again after the next shelf came back.
From the café window we watched the neighbouring port take down its Meridian board. Downstairs the enquiry bell kept ringing. A pilot already in the basin still had yesterday’s instructions in her cockpit. The exchange keeper stayed beside the receiver until the calls themselves stopped. Nobody could have heard that from the café.
The ferry pilot laid her strip of position fixes beside the harbour roll. Her strip went on for another three berths after the harbour roll ended. We asked the recorder to number one blank slip. Its wheels stood at nines. For the next watch I left that slip under the glass; anyone checking the radio could see where the reports had stopped.
The sorting clerk had tried the treasury line from her desk and heard it answer. She lent me her coin for the walk down to the quay. Same coin, same account, different relay: the quay spat it back. In the fault book we put the name of the hatch beside each result. That was the detail the treasury needed.
After a jump, the coolant return pipes click three times as they cool. Last watch, the starboard loop went quiet, though the gauges showed steady pressure. A technician found a jammed pipe support that held the line against the bulkhead. We freed it. Now after every jump, we listen for the clicks and check them against the temperature trace.
Long-Range Survey
The Star That Wasn’t There
A new point lit up on the sector chart. It moved with the antenna while the neighboring stars stayed put. Ice along the radiator’s edge was reflecting our own beacon. Before the next survey pass, we slewed the antenna two degrees and took a reference frame.
Habitation Deck
Night Watch and the Quiet Hatch
Four nights running, the pressure hatch by the galley reported closed before its latch clicked. Quiet mode slowed the drive, and the sensor only tracked the hatch position. We moved the closed signal to the latch limit switch. Now the bridge sees what the person standing at the hatch sees.
Incident Postmortems
Stillwater ·
Why the Pilot Lights Went Out
For 52 minutes crews could not count on a light to guide them into harbour. The passenger landing reopened six minutes before the freight approach.
The pilot register refused its next entry. The desks could still read a licence, but could no longer renew one.
Signal floats began losing their lights. Their self-check waited for the register; when it got no answer, each float restarted its own link.
With a spare register in service and the old volumes repacked, the passenger launch made the approach.
Test crossings on the freight side were passing consistently. The keeper stood down the skiff with the hand lamp.
Root cause
Cancelled entries still occupied space. Counting current pilots made the register look barely a third full. The binding had already reached its limit. A stalled register check could then take a working signal float out of service.
Follow-up
The watch wants a reading for space left in the binding. The next yard trial will hold the register silent and record which lights stay on.
The nearest berths disappeared from the booking book for several nights, although there was room on the water.
The near dates began closing as the book reached its new allowance.
The clerk moving the allowances noticed that several pontoons had closed together.
With the anchorage allowance corrected, the near dates were available again.
Root cause
The clerk copied a single pontoon’s allowance into the line for the entire anchorage. Every pontoon consulted that line before offering a berth.
Follow-up
The port proposed a second reader for changes to the book and separate minimum allowances for pontoons and anchorages. The inquiry records both proposals; adoption was still open.
For a quarter of an hour the parcel hatches in the schoolhouse yard could scarcely clear a collection. The far desk could neither find a parcel nor say what was owed on it.
The first failed lookups reached the watch.
A keeper called in from the hatches. The earlier trouble had returned.
The yard reported that collections could go ahead. Later repairs were entered separately.
Root cause
Slow searches held the ledger clerks at their desks. More requests queued for a clerk until the hatches failed even their ready check. The watch had carried the ledger across from the old yard without bringing over its warning for an overworked desk.
Follow-up
The yard subsequently changed how the books were indexed and revised the warning for long-held entries. The watch could not establish which action ended this particular stoppage.
The jump was delayed by 19 minutes. The safety interlock held the drive in standby.
The bridge saw the two course solutions disagree by 0.8°. Six minutes remained before the jump window.
The watch inhibited the jump and checked the heading against both star trackers.
After the backup computer restarted, both channels agreed. The bridge confirmed the new solution.
Asterion jumped on the recalculated trajectory.
Root Cause
After a brief power interruption, the backup computer loaded the previous day’s star catalog. Telemetry used the process start time to judge whether the catalog was current.
Corrective Actions
The bridge now checks the catalog versions on both channels before clearing the jump. On the test bench, we verify what happens when the backup starts with an outdated catalog.
Cryostorage · Cycle 2239
Green Screen, Warm Chamber
The panel displayed a stale temperature for Chamber Three for 11 minutes. The crew moved the samples to the adjacent chamber.
Chamber Three stopped sending readings after switching to the backup bus.
A technician spotted the rising temperature on the local display and moved the samples.
The watch restored the sensor link. The panel showed the current temperature.
Root Cause
The switchover stopped the compressor and interrupted the sensor link. The panel held the last reading and kept its status green.
Corrective Actions
After 90 seconds without a reading, the panel shows “No Data” and alerts the duty engineer. We added an independent local temperature alarm that works even when the bridge link is down.